What brick veneer establishes
On most new Texas houses, the brick is veneer: a single layer, or wythe, of brick standing in front of a wood-framed wall and attached to it with metal ties. It carries no load from the house. It is a cladding, and like any cladding it lets some water through. The design that makes it work is a drainage system behind the brick: an air space, a weather-resistive barrier on the sheathing, flashing at the base and over openings, and weep holes that let water out. As the International Code Council puts it, the air space, together with the barrier, flashing and weep holes, keeps the backing and stud walls dry.
The finished brick establishes how the house looks. Whether it stays dry depends on parts installed in the first few courses and then hidden.
The numbers the code sets
Section R703.8 of the International Residential Code (IRC) governs anchored masonry veneer. It calls for a nominal 1-inch minimum air space between the back of the brick and the sheathing. Corrosion-resistant metal ties connect the brick to the framing; in the common prescriptive layout, ties are spaced no more than 32 inches apart horizontally and 24 inches vertically, with each tie supporting no more than 2.67 square feet of wall. Flashing goes beneath the first course of brick above finished grade or the slab and over every window and door opening. Weep holes go immediately above that flashing, at a maximum of 33 inches on center and at least 3/16 inch in diameter. In Texas they are most often formed by leaving out the mortar in a vertical head joint.
The Brick Industry Association, the industry's technical body, recommends going further: open head joint weeps at no more than 24 inches on center.
Who checks it
Here the inspection record is thin. Prince William County, Virginia, says it directly: because brick veneer ties are not visible during any other required inspection, they are periodically spot-checked. In many jurisdictions, the brick goes up between the framing inspection and final with no inspection specifically aimed at it. The weep holes and base flashing are visible at final; the ties, the air space and the condition of the barrier behind the brick are not.
The defect that matters: a blocked air space
The most consequential problem is mortar dropped into the cavity while the mason lays brick. It piles up at the bottom of the wall, bridges the air space and blocks the weep holes from inside. Water that gets behind the brick, which some always does, then has nowhere to go but into the sheathing. The Institute of Building Enclosure Consultants issued a technical advisory in 2021 on problems with code-compliant brick veneer in houses, emphasizing that the air space must be kept clear. Mortar nets and drainage mats at the base of the wall reduce the risk.
The second problem is weep holes that are missing, sealed with caulk or paint, or buried by landscaping. A flowerbed raised above the weep line, or mulch piled against the brick, turns a drainage outlet into an inlet.
What still can be checked
After completion, look along the base of the brick and above each window and door. Weep holes should be present at roughly every third or fourth brick, open, and above the soil and mulch line, with flashing visible beneath them. Stains or efflorescence (white salt deposits) on the brick below windows can indicate water moving through the wall. The ties and the cavity can only be examined by removing brick or with a borescope through a weep.
Where the rules come from
Knox County, Tennessee's brick veneer handout summarizes the weep hole and flashing rules, and the Brick Industry Association's technical note on water penetration explains its tighter recommendation. The spot-check practice is from Prince William County's brick veneer inspection policy.